SPECIFICATIONS & TECHNICAL DATA
SANTORIN 21M2
Band pass active subwoofer
Drive unit: ø 21 cm (8 in) - type 21MT3
Frequency bandwidth:
29 - 150 Hz in semi-reverberating chamber
Maximum RMS SPL: 108 dB
Maximum output power: 200 W
Peak power: 400 W
Lowpass cut-off frequency: 20 to 200 Hz
Phase switch: 0° normal - 180° reverse
Input: 2 low level - 2 high level
Voltage: 115 / 230 V AC - 50 / 60 Hz
Maximum power consumption: 200 W
Standby power consumtion:
0.4W @ 230VAC --- 0.4W @ 115VAC
Power consumption when off:
0W @ 230VAC --- 0W @ 115VAC
Useable temperature range: +5°C to +35°C
Storage temperature: -5°C to +40°C
Useable humidity range: 40% to 70%
Dimensions (h x w x d): 33 x 33 x 36 cm - 13 x 13 x 14 in
Weight: 11 kg - 24 lbs
SANTORIN 25M2
Active subwoofer
Drive unit: ø 25 cm (10 in) - type 25S20
Frequency bandwidth:
28-150 Hz in semi-reverberating chamber
Maximum RMS SPL: 111 dB
Maximum output power: 200 W
Peak power: 400 W
Lowpass cut-off frequency: 20 to 200 Hz
Phase switch: 0° normal - 180° reverse
Input: 2 low level - 2 high level
Voltage: 115 / 230 V AC - 50 / 60 Hz
Maximum power consumption: 200 W
Standby power consumtion:
0.4W @ 230VAC --- 0.4W @ 115VAC
Power consumption when off:
0W @ 230VAC --- 0W @ 115VAC
Useable temperature range: +5°C to +35°C
Storage temperature: -5°C to +40°C
Useable humidity range: 40% to 70%
Dimensions (h x w x d): 42 X 36 X 38 cm - 16.5 x 14 x 15 in
Weight: 16 kg - 35 lbs
Because of technical improvements already under way in our
constant search for optimum quality, Cabasse reserves the right
to modify all the models presented in specification sheets, advertising
materials and manuals without prior notice.
Our web site www.cabasse.com will give you the specific adjustments
we recommend for the use of our active subwoofers.
Connections from the HI LEVEL OUTPUT
4
plugs
These outputs can be used to bring the signal to the main louds-
peaker systems or to a second subwoofer in a parallel mono confi-
guration. In the last lay-out, the L (left) and R (right) HI LEVEL
OUTPUT
4
terminals must be connected to the L (left) and R
(right) HI LEVEL INPUT
5
ones of the second subwoofer. The
input signal must then arrive into the first subwoofer by its L (left)
and R (right) HI LEVEL INPUT
5
terminals. The signal from the L
(left) and R (right) HI LEVEL OUTPUT
4
plugs is the one being
brought in by the HI LEVEL INPUT
5
connectors. These outputs
can thus be used to bring the signal to the main loudspeaker sys-
tems.
POWER SUPPLY
The AC IN
3
cord must be connected to the mains to supply the
subwoofer.
Switch POWER
1
on ON.
ADJUSTMENTS
LEVEL
7
For a first volume adjustment, position the CROSSOVER FRE-
QUENCY
8
at around 180 Hz, and turn slowly the volume LE-
VEL
7
clockwise from minimum level up to a position where you
feel that the subwoofer sound level is appropriate. A check of the
level adjustment will be necessary after following steps.
CROSSOVER FREQUENCY
8
This potentiometer adjusts the cut-off frequency which deter-
mines the working bandwidth of the subwoofer. This adjustment
should be done according to the specifications of the main spea-
kers and the room acoustics. Choose the best frequency after
various listening tests.
PHASE
9
For a better sound integration of the subwoofer in the main system,
the PHASE
9
of the subwoofer might have to be inverted (180° posi-
tion), depending on the distance between the subwoofer and the main
speakers. You have to check the PHASE
9
each time you move your
speakers and each time you adjust the CROSSOVER FREQUENCY
8
.
Attention, if you use 2 subwoofers, both phase switches must be on the
same position.
WEEE MARK
Disposal of Wastes of Electrical & Electronic Equip-
ment (Applicable in the European Union)
This symbol on the product, consisting of the crossed-
out wheeled bin, indicates that this product shall not be
treated as household waste. Instead it shall be handed
over to the applicable collection point for the disposal
of electrical and electronic equipment at the end of life.
By ensuring this product is disposed of correctly, you
will help prevent potential negative consequences for the environment
and human health, which could otherwise be caused by inappropriate
waste handling of this product. The recycling of materials will help to
preserve natural resources. For more detailed information about recy-
cling of this product, please contact your local city office, your house-
hold waste disposal service or the shop where you purchased the pro-
duct.
Attention
before operating the unit, be sure that the operating vol-
tage of your unit is identical with that of your local power
voltage. The selection of the right voltage 115 V - 230 V
is done with the selector 150 V - 230 V 2.